378 research outputs found
Design and Tests of the Silicon Sensors for the ZEUS Micro Vertex Detector
To fully exploit the HERA-II upgrade,the ZEUS experiment has installed a
Micro Vertex Detector (MVD) using n-type, single-sided, silicon micro-strip
sensors with capacitive charge division. The sensors have a readout pitch of
120 micrometers, with five intermediate strips (20 micrometer strip pitch). The
designs of the silicon sensors and of the test structures used to verify the
technological parameters, are presented. Results on the electrical measurements
are discussed. A total of 1123 sensors with three different geometries have
been produced by Hamamatsu Photonics K.K. Irradiation tests with reactor
neutrons and Co-60 photons have been performed for a small sample of sensors.
The results on neutron irradiation (with a fluence of 1 x 10^{13} 1 MeV
equivalent neutrons / cm^2) are well described by empirical formulae for bulk
damage. The Co-60 photons (with doses up to 2.9 kGy) show the presence of
generation currents in the SiO_2-Si interface, a large shift of the flatband
voltage and a decrease of the hole mobility.Comment: 33 pages, 25 figures, 3 tables, accepted for publication in NIM
Bi-directional Photogoniometer for the Assessment of the Luminous Properties of Fenestration Systems
Most energy saving applications of advanced fenestration systems (solar blinds, novel types of glazing and daylight redirecting devices) require a precise knowledge of their directional light transmission features. These photometric properties can be described by a Bi-directional Transmission Distribution Function (BTDF) whose experimental assessment requires appropriate equipment. A novel bi-directional transmission photogoniometer, based on digital imaging techniques, was designed and set up for that purpose. The apparatus takes advantage of a modern video image capturing device (CCD digital camera) as well as of powerful image analysis software (pattern recognition) to considerably reduce the scanning time of a BTDF measurement, in comparison to existing devices that use a conventional approach (mobile photometer). A detailed calibration and validation procedure was used to obtain optimal experimental accuracy for the device during the assessment of BTDF data. It included a spectral, a photometric and a geometrical calibration of the digital video system, as well as several additional corrections, leading to an overall relative accuracy better than 11% for BTDF data. A special effort was made to improve the user-friendliness of BTDF measurement by facilitating the data acquisition and treatment (definition of a data acquisition and electronic data format) and by offering different possibilities of BTDF visualisation (hemispherical representation, axonometric view of photometric solids, C-planes). Overall, the photometric equipment was used to assess the BTDFs of more than 20 novel fenestration products of the industrial partner of the project (Baumann-Hüppe Storen AG). The experimental data produced was successfully used by the company to optimise the visual and energy saving performance of their products, which confirms the adequacy of the novel bi-directional photogoniometer for practical building applications
Beam Test of Silicon Strip Sensors for the ZEUS Micro Vertex Detector
For the HERA upgrade, the ZEUS experiment has designed and installed a high
precision Micro Vertex Detector (MVD) using single sided micro-strip sensors
with capacitive charge division. The sensors have a readout pitch of 120
microns, with five intermediate strips (20 micron strip pitch). An extensive
test program has been carried out at the DESY-II testbeam facility. In this
paper we describe the setup developed to test the ZEUS MVD sensors and the
results obtained on both irradiated and non-irradiated single sided micro-strip
detectors with rectangular and trapezoidal geometries. The performances of the
sensors coupled to the readout electronics (HELIX chip, version 2.2) have been
studied in detail, achieving a good description by a Monte Carlo simulation.
Measurements of the position resolution as a function of the angle of incidence
are presented, focusing in particular on the comparison between standard and
newly developed reconstruction algorithms.Comment: 41 pages, 21 figures, 2 tables, accepted for publication in NIM
Global long-term monitoring of the ozone layer - a prerequisite for predictions
Although the Montreal Protocol now controls the production and emission of ozone depleting substances, the timing of ozone recovery is unclear. There are many other factors affecting the ozone layer, in particular climate change is expected to modify the speed of re-creation of the ozone layer. Therefore, long-term observations are needed to monitor the further evolution of the stratospheric ozone layer. Measurements from satellite instruments provide global coverage and are supplementary to selective ground-based observations. The combination of data derived from different space-borne instruments is needed to produce homogeneous and consistent long-term data records. They are required for robust investigations including trend analysis. For the first time global total ozone columns from three European satellite sensors GOME (ERS-2), SCIAMACHY (ENVISAT), and GOME-2 (METOP-A) are combined and added up to a continuous time series starting in June 1995.
On the one hand it is important to monitor the consequences of the Montreal Protocol and its amendments; on the other hand multi-year observations provide the basis for the evaluation of numerical models describing atmospheric processes, which are also used for prognostic studies to assess the future development. This paper gives some examples of how to use satellite data products to evaluate model results with respective data derived from observations, and to disclose the abilities and deficiencies of atmospheric models. In particular, multi-year mean values derived from the Chemistry-Climate Model E39C-A are used to check climatological values and the respective standard deviations
The synthetic antimicrobial peptide 19-2.5 attenuates septic cardiomyopathy and prevents down-regulation of SERCA2 in polymicrobial sepsis
LM has received grants by the Faculty of Medicine at the RWTH Aachen University (START 15/14 and
START 46/16) and the Deutsche Forschungsgemeinschaft (DFG, MA 7082/1–1). This work was supported by
the Immunohistochemistry and Confocal Microscopy Unit, a core facility of the Interdisciplinary Centre for
Clinical Research (IZKF) Aachen, within the Faculty of Medicine at the RWTH Aachen University and the
RWTH centralized Biomaterial Database (RWTH cBMB) of the University Hospital RWTH Aachen. We are
very grateful to Antons Martincuks M.Sc. and Professor Gerhard Müller-Newen for live-cell imaging. This work
was supported, in part, by the University of Turin (ex-60% 2015A and B) and by the William Harvey Research
Foundation and forms part of the research themes contributing to the translational research portfolio of Barts
and the London Cardiovascular Biomedical Research Unit that is supported and funded by the National Institute
for Health Research. This work also contributes to the Organ Protection research theme of the Barts Centre for
Trauma Sciences supported by the Barts and The London Charity (Award 753/1722)
Targeted delivery of a phosphoinositide 3-kinase γ inhibitor to restore organ function in sepsis
Jaundice, the clinical hallmark of infection-associated liver dysfunction, reflects altered membrane organization of the canalicular pole of hepatocytes and portends poor outcomes. Mice lacking phosphoinositide 3-kinase-γ (PI3Kγ) are protected against membrane disintegration and hepatic excretory dysfunction. However, they exhibit a severe immune defect that hinders neutrophil recruitment to sites of infection. To exploit the therapeutic potential of PI3Kγ inhibition in sepsis, a targeted approach to deliver drugs to hepatic parenchymal cells without compromising other cells, in particular immune cells, seems warranted. Here, we demonstrate that nanocarriers functionalized through DY-635, a fluorescent polymethine dye, and a ligand of organic anion transporters can selectively deliver therapeutics to hepatic parenchymal cells. Applying this strategy to a murine model of sepsis, we observed the PI3Kγ-dependent restoration of biliary canalicular architecture, maintained excretory liver function, and improved survival without impairing host defense mechanisms. This strategy carries the potential to expand targeted nanomedicines to disease entities with systemic inflammation and concomitantly impaired barrier functionality
Use of IFN gamma/IL10 Ratio for Stratification of Hydrocortisone Therapy in Patients With Septic Shock
Large clinical trials testing hydrocortisone therapy in septic shock have produced conflicting results. Subgroups may benefit of hydrocortisone treatment depending on their individual immune response. We performed an exploratory analysis of the database from the international randomized controlled clinical trial Corticosteroid Therapy of Septic Shock (CORTICUS) employing machine learning to a panel of 137 variables collected from the Berlin subcohort comprising 83 patients including demographic and clinical measures, organ failure scores, leukocyte counts and levels of circulating cytokines. The identified theranostic marker was validated against data from a cohort of the Hellenic Sepsis Study Group (HSSG) (n = 246), patients enrolled in the clinical trial of Sodium Selenite and Procalcitonin Guided Antimicrobial Therapy in Severe Sepsis (SISPCT, n = 118), and another, smaller clinical trial (Crossover study, n = 20). In addition, in vitro blood culture experiments and in vivo experiments in mouse models were performed to assess biological plausibility. A low serum IFNγ/IL10 ratio predicted increased survival in the hydrocortisone group whereas a high ratio predicted better survival in the placebo group. Using this marker for a decision rule, we applied it to three validation sets and observed the same trend. Experimental studies in vitro revealed that IFNγ/IL10 was negatively associated with the load of (heat inactivated) pathogens in spiked human blood and in septic mouse models. Accordingly, an in silico analysis of published IFNγ and IL10 values in bacteremic and non-bacteremic patients with the Systemic Inflammatory Response Syndrome supported this association between the ratio and pathogen burden. We propose IFNγ/IL10 as a molecular marker supporting the decision to administer hydrocortisone to patients in septic shock. Prospective clinical studies are necessary and standard operating procedures need to be implemented, particularly to define a generic threshold. If confirmed, IFNγ/IL10 may become a suitable theranostic marker for an urging clinical need
Measurement of inclusive D*+- and associated dijet cross sections in photoproduction at HERA
Inclusive photoproduction of D*+- mesons has been measured for photon-proton
centre-of-mass energies in the range 130 < W < 280 GeV and a photon virtuality
Q^2 < 1 GeV^2. The data sample used corresponds to an integrated luminosity of
37 pb^-1. Total and differential cross sections as functions of the D*
transverse momentum and pseudorapidity are presented in restricted kinematical
regions and the data are compared with next-to-leading order (NLO) perturbative
QCD calculations using the "massive charm" and "massless charm" schemes. The
measured cross sections are generally above the NLO calculations, in particular
in the forward (proton) direction. The large data sample also allows the study
of dijet production associated with charm. A significant resolved as well as a
direct photon component contribute to the cross section. Leading order QCD
Monte Carlo calculations indicate that the resolved contribution arises from a
significant charm component in the photon. A massive charm NLO parton level
calculation yields lower cross sections compared to the measured results in a
kinematic region where the resolved photon contribution is significant.Comment: 32 pages including 6 figure
Measurement of the diffractive structure function in deep inelastic scattering at HERA
This paper presents an analysis of the inclusive properties of diffractive
deep inelastic scattering events produced in interactions at HERA. The
events are characterised by a rapidity gap between the outgoing proton system
and the remaining hadronic system. Inclusive distributions are presented and
compared with Monte Carlo models for diffractive processes. The data are
consistent with models where the pomeron structure function has a hard and a
soft contribution. The diffractive structure function is measured as a function
of \xpom, the momentum fraction lost by the proton, of , the momentum
fraction of the struck quark with respect to \xpom, and of . The \xpom
dependence is consistent with the form \xpoma where
in all bins of and
. In the measured range, the diffractive structure function
approximately scales with at fixed . In an Ingelman-Schlein type
model, where commonly used pomeron flux factor normalisations are assumed, it
is found that the quarks within the pomeron do not saturate the momentum sum
rule.Comment: 36 pages, latex, 11 figures appended as uuencoded fil
- …